Short Description: |
MCCB SEALING ACCESSORIES
|
DIRECT ROTARY HANDLE BLACK GV4 BV4
|
COIL ST MX 380-480V AC FOR GV4 BV4
|
KIT 6 LIMITED TORQUE THROWAWAY SCREW 5 N
|
OPEN DOOR SHAFT OPERATOR NSXM PP B GV4
|
EXTENDED ROTARY HANDLE RED GV4 BV4
|
COIL UVR MN 380-415V 50HZ FOR GV4 BV4
|
LATERAL ROT HANDLE BLACK NSXM PP-B GV4
|
COIL ST MX 24V AC/DC FOR GV4 BV4
|
KIT 6 LIMITED TORQUE THROWAWAY SCREW 9 N
|
Schneider Extended Rotary Handle Black GV4 BV4
|
DIRECT ROTARY HANDLE RED GV4 BV4
|
EXTENDED ROTARY HANDLE RED IP65 GV4 BV4
|
PHASE BARRIER IEC/UL DIS AND VIGI AND GV
|
COIL ST MX 110-130V AC/DC FOR GV4 BV4
|
COIL ST MX 208-277V 50/60HZ FOR GV4 BV4
|
AUXILIARY CONTACT OF OR SD GV4 & BV4
|
Schneider Lock Toggle Device Rem Padlockable
|
COIL UVR MN 24V AC/DC FOR GV4 BV4
|
SPREADER 3P IEC DIS AND GV4
|
COIL UVR MN 110-130V AC/DC FOR GV4 BV4
|
COIL UVR MN 208-240V 50/60HZ FOR GV4 BV4
|
Long Description: |
This is a bag of sealing accessories for Compact NSX 100/160/250 devices. Seals can be used for the toggle, rotary handle, motor mechanism, trip unit, front cover and terminal shields. A bag contains 6 sealing accessories, 6 lead seals, 2 screws and 0.5m of wire.
|
TeSys GV direct rotary handle, for motor circuit breakers GV4PE, LE, PEM, PB or replacement part for GV4P, GV4L handle. For main switch usage, it provides a black handle on a black bezel with indication of 3 positions OFF, ON, TRIP. Equipped with a "push to trip" button. Padlockable in OFF or ON position with up to 3 padlocks (to be ordered separately). Locking in ON position does not prevent the circuit breaker from tripping (unlocking is required for fault reset). Green Premium compliant (RoHS/REACh).
|
TeSys GV electrical trip unit, MX shunt trip, 380-415V AC 50Hz / 440-480V AC 60Hz, for motor circuit breakers GV4. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal. To be plugged inside the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
|
It is a set of 6 torque limiting breakaway bits for 3 poles Compact NSXm and PowerPact B devices. They are used to tighten at the right torque Everlink connectors, compression lugs or busbar power connections. These breakaway bits are in yellow to indicate that the limiting torque is 5 N.m.
|
This is an open door shaft operator accessory for extended rotary handle. This accessory is compatible with Compact NSXm, Compact NSX and PowerPact B products. It is used to operate the device when the switchboard door is open. This accessory complies with UL 508A standard.
|
TeSys GV extended rotary handle, for motor circuit breakers GV4 mounted inside an enclosure and to be operated externally. For emergency switch usage, it provides a red handle on yellow front plate with indication of 3 positions OFF, ON, TRIP. To be mounted on the door of the enclosure, the handle mechanism ensures an IP54 protection to the mounting. It also includes a mounting adaptor to be screwed on the face of the circuit breaker, and an extension shaft to be be adjusted in length (distance between the door and the back of the circuit breaker must be in range 214-627mm). Padlockable in OFF position with up to 3 padlocks (to be ordered separately). Green Premium compliant (RoHS/REACh).
|
TeSys GV electrical trip unit, MN undervoltage release, 380-415V AC 50Hz, for motor circuit breakers GV4. Opening of the the circuit breaker is ensured when the control voltage drops below 0.35 Uc, and possible between 0.35-0.7 Uc. Closing of the circuit breaker is possible when the control voltage is in limits 0.85-1.1 Uc. To be plugged inside the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA), Green Premium compliant (RoHS/REACh).
|
This side rotary handle is a control accessory for Compact NSXm and PowerPact B devices. The circuit breaker installed in a switchboard with this side rotary handle is IP54 according to IEC 60529 standard. It makes possible to operate the device from the side up to 480 mm extension and it maintains suitability for isolation. The shaft length is adjustable. This accessory has a black handle on a black front. It can be packlocked in the OFF position by using one to three padlocks.
|
TeSys GV electrical trip unit, MX shunt trip, 24V AC 50Hz/60Hz or 24V DC, for motor circuit breakers GV4. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal. To be plugged inside the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
|
It is a set of 6 torque limiting breakaway bits for 3 poles Compact NSXm and PowerPact B devices. They are used to tighten at the right torque Everlink connectors, compression lugs or busbar power connections. These breakaway bits are coloured in green to indicate that the limiting torque is 9 N.m.
|
TeSys GV extended rotary handle, for motor circuit breakers GV4 mounted inside an enclosure and to be operated externally. For main switch usage, it provides a black handle on grey front plate with indication of 3 positions OFF, ON, TRIP. To be mounted on the door of the enclosure, the handle mechanism ensures an IP54 protection to the mounting. It also includes a mounting adaptor to be screwed on the face of the circuit breaker, and an extension shaft to be be adjusted in length (distance between the door and the back of the circuit breaker must be in range 214-627mm). Padlockable in OFF or ON position with up to 3 padlocks (to be ordered separately). Locking in ON position does not prevent the circuit breaker from tripping (unlocking is required for fault reset). Green Premium compliant (RoHS/REACh).
|
TeSys GV direct rotary handle, for motor circuit breakers GV4PE, LE, PEM, PB. For emergency switch usage, it provides a red handle on a yellow bezel with indication of 3 positions OFF, ON, TRIP. Equipped with a "push to trip" button. Padlockable in OFF position with up to 3 padlocks (to be ordered separately). Green Premium compliant (RoHS/REACh).
|
TeSys GV extended rotary handle, for motor circuit breakers GV4 mounted inside an enclosure and to be operated externally. For emergency switch usage, it provides a red handle on yellow front plate with indication of 3 positions OFF, ON, TRIP. To be mounted on the door of the enclosure, the handle mechanism ensures an IP65 protection to the mounting. It also includes a mounting adaptor to be screwed on the face of the circuit breaker, and an extension shaft to be be adjusted in length (distance between the door and the back of the circuit breaker must be in range 214-627mm). Padlockable in OFF position with up to 3 padlocks (to be ordered separately). Green Premium compliant (RoHS/REACh).
|
It is an insulation accessory for Compact NSXm and PowerPact B devices. These interphase barriers increase the insulation level at the power connection points. They can be clipped easily onto the device. They are not compatible with the long terminal shields. These parts comes in sets of 6.
|
TeSys GV electrical trip unit, MX shunt trip, 110-130V AC 50Hz/60Hz or 125V DC, for motor circuit breakers GV4. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal. To be plugged inside the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
|
TeSys GV electrical trip unit, MX shunt trip, 208-240V AC 50Hz/60Hz, for motor circuit breakers GV4. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal. To be plugged inside the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
|
TeSys GV4 auxiliary contact block, for motor circuit breakers GV4. 1C/O contact, it performs Open/Close OF function or Trip alarm SD function, depending of its location in the circuit breaker. Rated for operation up to 5A/690V AC and 5A/250V DC. To be plugged inside the circuit breaker, in the right-hand cavity for OF function, in the left-hand cavity for SD function, connection by spring terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
|
It is a removable toggle padlocking device for circuit breakers. This locking accessory is compatible with Compact NSXm, Compact NSX, PowerPact B and EasyPact CVS products. It can receive up to three padlocks with diameter of 5 to 8 mm and is used to lock Compact NSXm in OFF position only. Locking in the OFF position ensures isolation as per IEC 60947-2.
|
TeSys GV electrical trip unit, MN undervoltage release, 24V AC 50/60Hz and 24V DC, for motor circuit breakers GV4. Opening of the the circuit breaker is ensured when the control voltage drops below 0.35 Uc, and possible between 0.35-0.7 Uc. Closing of the circuit breaker is possible when the control voltage is in limits 0.85-1.1 Uc. To be plugged inside the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA), Green Premium compliant (RoHS/REACh).
|
It is a set of 3 spreaders used to increase the pitch between the poles from 21 mm to 35 mm. It is used on compact NSXm and PowerPact B devices. Bares and cable lugs are attached to the end of the spreaders. These accessories are supplied with M8 screws for power connection and 2 interphase barriers.
|
TeSys GV electrical trip unit, MN undervoltage release, 110-130V AC 50/60Hz and 125V DC, for motor circuit breakers GV4. Opening of the the circuit breaker is ensured when the control voltage drops below 0.35 Uc, and possible between 0.35-0.7 Uc. Closing of the circuit breaker is possible when the control voltage is in limits 0.85-1.1 Uc. To be plugged inside the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA), Green Premium compliant (RoHS/REACh).
|
TeSys GV electrical trip unit, MN undervoltage release, 208-240V AC 50/60Hz, for motor circuit breakers GV4. Opening of the the circuit breaker is ensured when the control voltage drops below 0.35 Uc, and possible between 0.35-0.7 Uc. Closing of the circuit breaker is possible when the control voltage is in limits 0.85-1.1 Uc. To be plugged inside the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA), Green Premium compliant (RoHS/REACh).
|