Short Description: |
GV2M MOUNTING PLATE - SCREW
|
MCB SHUNT TRIP INRS 110V-50
|
Schneider Plate
|
MCB SHUNT TRIP INRS 220V-50
|
MCB UNDERVOLTAGE TRIP 115V RHS MT
|
MCB AUXILIARY CONTACT N/O FAULT+N/C LHS
|
GV2 SHUNT TRIP 415V RHS MOUNT
|
MOTOR STARTER PROTECTOR CURRENT LIMITER FOR LUB 2
|
MPCB SHUNT TRIP 115VAC RHS MNT GV2
|
TERMINAL BLOCK 3POLE 63A FOR GV2G BUS BAR SETS
|
Schneider MPCB Connection Flexible for GV2 to LC1D09/D25
|
UNDERVOLTAGE TRIP GV2 380V RHS MOUNT
|
Schneider Terminal Block 3 Pole 63A H5.8xL5.6mm for GV2 Gang Bus Bar Sets
|
GV2ME SHUNT TRIP INRS 380V 50HZ
|
Schneider Auxiliary Contact Block 1N/C 1N/O Left-Hand Side Mounting for GV2/GV3&GV7 Series
|
GV2 SHUNT TRIP 240V RHS MOUNT
|
UNDERVOLTAGE TRIP GV2 240V RHS MOUNT
|
Schneider GV2 Auxiliary Normally Open (Fault) + Normally Open Left Hand Side
|
Schneider Busbar for MPCB 63A 690V 4 Tap-Off 45mm Pitch 4 Center GV3
|
Schneider Bus Bar 63A 45mm Pitch GV2 Gang345
|
Schneider Auxiliary Contact Block 1N/C 1N/O Front Mounting for GV2/GV3&GV7 Series
|
Schneider Combination Block GV2-LC1D09/D38 for Motor Starter
|
AUXILIARY 100KA CURRENT LIMITER GV2
|
Schneider Busbar for MPCB 63A 690V 2 Tap-Off 45mm Pitch 2 Center GV2
|
MPCB BLOCK COMBINATION GV2 LC1D LAD31
|
Long Description: |
TeSys GV accessory, mounting adapter plate for motor circuit breakers GV2. For mounting a GV2 on panel by screw fixing. Sold in lots of 10 units. Green Premium compliant (RoHS/REACh).
|
TeSys GV electrical trip add-on block, MN undervoltage trip conforming to INRS and VDE 0113, 110-115V AC 50Hz / 127V AC 60Hz, for TeSys GV2ME motor circuit breakers. It trips the circuit breaker when the control voltage drops in limits 0.7-0.35 Uc. To be installed on right-hand RH side of the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
|
TeSys D mounting plate, for motor starter assembly made with a motor circuit breaker GV2 or fuse carrier LS1D32 and a contactor LC1D09-D38. It permits to have a compact motor starter assembly with front faces aligned devices. The plate is to be fixed on 2 x 35mm DIN-rails by clip-on. Other accessories (terminals blocks, busbars, combination blocks) for motor starter assembly are available (to be ordered separately). Green Premium compliant (RoHS/REACh).
|
TeSys GV electrical trip add-on block, MN undervoltage trip conforming to INRS and VDE 0113, 220-240V AC 50Hz, for TeSys GV2ME motor circuit breakers. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc. To be installed on right-hand RH side of the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
|
TeSys GV electrical trip unit, MN undervoltage release, 110-115V AC 50Hz / 127V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage drops below 0.35 Uc, possible opening between 0.35-0.7 Uc. Closing of the circuit breaker is possible when the control voltage is in limits 0.85-1.1 Uc. To be mounted on the right-hand side of the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
|
TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NO fault signaling contact + 1NC instantaneous auxiliary contact. Instantaneous auxiliary contact rated for operation up to 6A/690V AC and 6A/240V DC. Fault signaling contact rated for operation up to 2A/240V AC and 1A/60V DC. To be installed on left-hand side of the circuit breaker (1 block mounting maximum), connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
|
TeSys GV electrical trip unit, MX shunt trip, 380-400V AC 50Hz / 440V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal. To be mounted on the right-hand side of the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
|
TeSys Integral short circuit current limiter block for contactor breakers Integral 63, motor circuit breakers TeSys GV2, starter controllers TeSys U. It increases the ability of the circuit breaker to withstand a short circuit current from 50 kA to 100/130kA@400 V. To be connected upstream of one or multiple circuit breakers with a total motor nominal current of 32A. For clipping on a 35mm DIN rail or screw fixing, independant mounting from the protection device. It conforms to RoHS/REACh regulation.
|
TeSys GV electrical trip unit, MX shunt trip, 110-115V AC 50Hz / 127V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal. To be mounted on the right-hand side of the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
|
TeSys GV terminal block, 3 phases, 63A/690V, to supply busbar sets GV2G. To be mounted next to the devices connected by the busbar sets, on the same DIN rail, and connected by one of the busbar outlets. It can be fitted with a current limiter GV1L3 for all parallel motor starters (to be ordered separately). Connection to the supply cable by screw connectors. Green Premium compliant (RoHS/REACh).
|
TeSys GV2 - flexible connection - 3P - with contactor LC1D09...25 has a part number of GV1G02, and is part of the TeSys GV2 range of products by Schneider Electric. Measuring at 3.5CM tall, 9CM wide, 12CM deep, and has a weight of 11G. The barcode of this product is 3389110212303.
|
TeSys GV electrical trip unit, MN undervoltage release, 380-400V AC 50Hz / 440V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage drops below 0.35 Uc, possible opening between 0.35-0.7 Uc. Closing of the circuit breaker is possible when the control voltage is in limits 0.85-1.1 Uc. To be mounted on the right-hand side of the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
|
TeSys GV terminal block, 3 phases, 63A/690V, to supply busbar sets GV2G. To be inserted directly on the top terminals of the devices connected by the busbar sets. Connection to the supply cable by screw connectors. Green Premium compliant (RoHS/REACh).
|
TeSys GV electrical trip add-on block, MN undervoltage trip conforming to INRS and VDE 0113, 380-400V AC 50Hz / 440V AC 60Hz, for TeSys GV2ME motor circuit breakers. It trips the circuit breaker when the control voltage drops in limits 0.7-0.35 Uc. To be installed on right-hand RH side of the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
|
TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NO+1NC instantaneous auxiliary contacts. Rated for operation up to 6A/690V AC and 6A/240V DC. To be installed on left-hand side of the circuit breaker (2 blocks mounting possible), connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
|
TeSys GV electrical trip unit, MX shunt trip, 220-240V AC 50Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal. To be mounted on the right-hand side of the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
|
TeSys GV electrical trip unit, MN undervoltage release, 220-240V AC 50Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage drops below 0.35 Uc, possible opening between 0.35-0.7 Uc. Closing of the circuit breaker is possible when the control voltage is in limits 0.85-1.1 Uc. To be mounted on the right-hand side of the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
|
TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NO fault signaling contact + 1NO instantaneous auxiliary contact. Instantaneous auxiliary contact rated for operation up to 6A/690V AC and 6A/240V DC. Fault signaling contact rated for operation up to 2A/240V AC and 1A/60V DC. To be installed on left-hand side of the circuit breaker (1 block mounting maximum), connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
|
TeSys GV busbar set, 3 phases, 63A/690V, for the upstream parallel wiring of groups of motor starters composed of GV2 motor circuit breakers or LS1D32 fuse carriers. For use with screw clamp terminal devices, it is composed of 4 tap-off outlets for the paralleling of 4 devices with a pitch of 45mm. The use of a terminal block GV1G09 or GV2G05 is recommended to supply the busbar sets (to be ordered separately). Green Premium compliant (RoHS/REACh).
|
TeSys GV busbar set, 3 phases, 63A/690V, for the upstream parallel wiring of groups of motor starters composed of GV2 motor circuit breakers or LS1D32 fuse carriers. For use with screw clamp terminal devices, it is composed of 3 tap-off outlets for the paralleling of 3 devices with a pitch of 45mm. The use of a terminal block GV1G09 or GV2G05 is recommended to supply the busbar sets (to be ordered separately). Green Premium compliant (RoHS/REACh).
|
TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NO+1NC instantaneous auxiliary contacts. Rated for operation up to 2A/240V AC and 1A/60V DC. To be installed on front side of the circuit breaker, connection by screw clamp terminals. Sold in lots of 10 units. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
|
TeSys GV accessory, combination block for motor starter assembly. For the connection between a motor circuit breaker GV2 or a fuse carrier LS1D32 and contactor LC1D09-D38. To be used when the assembly is mounted directly on DIN rails. Sold in lots of 10 units. Green Premium compliant (RoHS/REACh).
|
TeSys GV short circuit current limiter block for motor circuit breakers GV2L/LE/P/ME/RT. It increases the ability of the circuit breaker to withstand a short circuit current from 50 kA to 100/130kA@400 V. To be mounted on top of a GV2 motor circuit breaker. It conforms to RoHS/REACh regulation.
|
TeSys GV busbar set, 3 phases, 63A/690V, for the upstream parallel wiring of groups of motor starters composed of GV2 motor circuit breakers or LS1D32 fuse carriers. For use with screw clamp terminal devices, it is composed of 2 tap-off outlets for the paralleling of 2 devices with a pitch of 45mm. The use of a terminal block GV1G09 or GV2G05 is recommended to supply the busbar sets (to be ordered separately). Green Premium compliant (RoHS/REACh).
|
TeSys GV accessory, combination block for motor starter assembly. For the connection between a motor circuit breaker GV2 or a fuse carrier LS1D32 and a contactor LC1D09-D38. To be used when the assembly uses a mounting bracket LAD311. Sold in lots of 10 units. Green Premium compliant (RoHS/REACh).
|
Manufacturer Name: |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
SCHNEIDER ELECTRIC AUSTRALIA PTY LTD |
AdditionalDescription: |
TESYS GV2 - ADAPTOR PLATE - BY SCREW FIXING |
TESYS GV2 - SAFETY UNDERVOLTAGE TRIP - 110...115 V AC 50HZ |
MOUNTING BRACKET, IEC CONTACTORS |
TESYS GV2 - SAFETY UNDERVOLTAGE TRIP - 220...240 V AC 50 HZ |
TESYS GV2 & GV3 - UNDERVOLTAGE TRIP - 110...115 V AC 50HZ |
TESYS GV2 & GV3 - AUXILIARY CONTACT - 1 NC + 1 NO (FAULT) |
TESYS GV2 & GV3 - SHUNT TRIP - 380...400V AC 50HZ |
TESYS GV2 - LIMITERS - ON RAIL |
TESYS GV2 & GV3 - SHUNT TRIP - 110...115 V AC 50HZ |
TESYS GV2, TESYS D & TESYS U - TERMINAL BLOCK - 3P - FOR GV1L3 |
TESYS GV2 - FLEXIBLE CONNECTION - 3P - WITH CONTACTOR LC1D09...25 |
TESYS GV2 & GV3 - UNDERVOLTAGE TRIP - 380...400V AC 50HZ |
TESYS GV2, TESYS D & TESYS U - TERMINAL BLOCK - 3P - FROM THE TOP |
|
TESYS GV2 & GV3 - AUXILIARY CONTACT BLOCK - 1 NO + 1 NC |
TESYS GV2 & GV3 - SHUNT TRIP - 220...240 V AC 50 HZ |
TESYS GV2 & GV3 - UNDERVOLTAGE TRIP - 220...240 V AC 50 HZ |
TESYS GV2 & GV3 - AUXILIARY CONTACT - 1 NO + 1 NO (FAULT) |
LINERGY FT - COMB BUSBAR - 63 A - 4 TAP-OFFS - 45 MM PITCH |
LINERGY FT - COMB BUSBAR - 63 A - 3 TAP-OFFS - 45 MM PITCH |
TESYS GV2 & GV3 - AUXILIARY CONTACT - 1 NO + 1 NC |
TESYS GV2 - COMBINATION BLOCKS - WITH CONTACTOR LC1D09...D38 |
TESYS GV2 - LIMITERS - ON CIRCUIT BREAKER |
LINERGY FT - COMB BUSBAR - 63 A - 2 TAP-OFFS - 45 MM PITCH |
TESYS GV2 - COMBINATION BLOCKS - WITH LAD311 AND CONTACTOR LC1D09...D38 |